Difference between revisions of "103891"
Line 15: | Line 15: | ||
* Sync cable example: [http://www.digikey.com/product-detail/en/tensility-international-corp/10-00331/839-1029-ND/2350237 839-1029-ND] | * Sync cable example: [http://www.digikey.com/product-detail/en/tensility-international-corp/10-00331/839-1029-ND/2350237 839-1029-ND] | ||
+ | Connector provides high-current (up to 0.5A) dc-coupled 5V output and optoisolated I/O. When optoisolated pair is used used as an input (common use), external signal is applied between XSYNC1 (+) and XSYNC2(-). When the pair is used as an output (less common), external 5V power source should be connected in series with the receiver and 103891, so that "+" will be applied to XSYNC2, and "-" - to XSYNC1 (opposite to the input mode). Details are available in the circuit diagram of the [[10389]] board. | ||
+ | |||
+ | Output synchronization can be just a pulse or carry additional timestamp data when used to synchronize multiple NC393 cameras. See [[Trigger_393]] for the settings. | ||
{| class='wikitable' | {| class='wikitable' | ||
|+Connector pinout | |+Connector pinout | ||
Line 23: | Line 26: | ||
|- | |- | ||
|XSYNC1 | |XSYNC1 | ||
− | | | + | |1 |
|black | |black | ||
|optoisolated, "+" input with respect to XSYNC2 | |optoisolated, "+" input with respect to XSYNC2 | ||
|- | |- | ||
|SYNC_DRV | |SYNC_DRV | ||
− | | | + | |2 |
|red | |red | ||
|Sync output (DC-coupled), +5V pulses with respect to GND | |Sync output (DC-coupled), +5V pulses with respect to GND | ||
|- | |- | ||
|GND | |GND | ||
− | | | + | |3 |
|white | |white | ||
|Output reference, connected to the camera system ground | |Output reference, connected to the camera system ground | ||
|- | |- | ||
|XSYNC2 | |XSYNC2 | ||
− | | | + | |4 |
|green | |green | ||
|optoisolated, "-" input with respect to XSYNC1 | |optoisolated, "-" input with respect to XSYNC1 |
Revision as of 10:51, 31 January 2018
103891 adapter board routes external sync I/O from the 10389 interface board to the back panel 2.5mm barrel connector and provide 4-pic connector socket for 3.3V/5.0V fan. It is used in Elphel 393 series cameras
Mechanical properties
- Dimensions: 58 x 38 x 9 mm (all connectors installed)
- Weight: 3.0 g
- Mechanical drawings and CAD files for the 103891 board: link
|
Copyright © 2024 Elphel Inc., Licensed under [1], GNU FDL v.1.3 | ||
Links
- J2 connector: SJ1-42534-SMT-TR (datasheet)
- Sync cable example: 839-1029-ND
Connector provides high-current (up to 0.5A) dc-coupled 5V output and optoisolated I/O. When optoisolated pair is used used as an input (common use), external signal is applied between XSYNC1 (+) and XSYNC2(-). When the pair is used as an output (less common), external 5V power source should be connected in series with the receiver and 103891, so that "+" will be applied to XSYNC2, and "-" - to XSYNC1 (opposite to the input mode). Details are available in the circuit diagram of the 10389 board.
Output synchronization can be just a pulse or carry additional timestamp data when used to synchronize multiple NC393 cameras. See Trigger_393 for the settings.
Name | Pin | Cable wire color | Description |
XSYNC1 | 1 | black | optoisolated, "+" input with respect to XSYNC2 |
SYNC_DRV | 2 | red | Sync output (DC-coupled), +5V pulses with respect to GND |
GND | 3 | white | Output reference, connected to the camera system ground |
XSYNC2 | 4 | green | optoisolated, "-" input with respect to XSYNC1 |