Focus adjustment 393: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
| Line 14: | Line 14: | ||
# adjust screws | # adjust screws | ||
# repeat from 4. until good | # repeat from 4. until good | ||
==Setup== | |||
===Parts=== | |||
* Assembled SFE without lens and without IR-cut filter (can be with the filter if the target lens is different) | |||
* M12 adapter | |||
* 2 spacers: 5mm and 4.7mm (shaved off 0.3mm (made from 5mm spacer) for optimal adjustment) | |||
* Lens N125B04530W with IR-cut filter. If the target lens is different, still use this one for adjustment then replace. Wrap the thread of the lens with the teflon tape for better thread fitting - 2 layers if enough. When screwing in make sure the tape does not get in the optical path. | |||
{| | |||
|[[File:SFE focusing parts.jpeg|thumb|500px|Fig.2 SFE parts]] | |||
|} | |||
* Focus adjustment screws - do not overtighten initially. Later, right before starting the procedure when the camera is against the pattern - turn it on, while in jpeg open the control interface and adjust the screws for the best manual focus (do not apply too much force). | |||
{| | |||
|[[File:SFE focusing SFE screws.jpeg|thumb|200px|Fig.3 Focus adjustment screws]] | |||
|} | |||
===Assembled setup=== | |||
* Take a longer cable - at least 100mm | |||
* Connect to port 0 | |||
* Set the camera address to 192.168.0.38 | |||
* Make sure the power supply provides the right voltage - 12V or 48V. If possible install PoE compatible power board - 10386. | |||
{| | |||
|[[File:SFE focusing camera.jpeg|thumb|200px|Fig.4 Assembled focusing setup]] | |||
|} | |||
===Pattern=== | |||
* Use the wallpaper pattern | |||
{| | |||
|valign='top'|[[File:SFE focusing tripod.jpeg|thumb|200px|Fig.5 Tripod placement]] | |||
|valign='top'|[[File:SFE focusing tripod closer.jpeg|thumb|200px|Fig.6 Tripod closeup]] | |||
|} | |||
* Make sure all 4 lasers are pointing in the right spots - "manual laser pointers" yellow button in the imagej plugin | |||
{| | |||
|valign='top'|[[File:SFE focusing laser spots.jpeg|thumb|200px|Fig.7 Laser spot markings]] | |||
|} | |||
Revision as of 18:49, 2 October 2020
Description
internal use
regular SFE
- used on big the Xeon PC - 192.168.0.6
- restore from test_focusing/default.conf-xml
- quick get&show
- find grid
- no-move measure
- show PSF
- adjust screws
- repeat from 4. until good
Setup
Parts
- Assembled SFE without lens and without IR-cut filter (can be with the filter if the target lens is different)
- M12 adapter
- 2 spacers: 5mm and 4.7mm (shaved off 0.3mm (made from 5mm spacer) for optimal adjustment)
- Lens N125B04530W with IR-cut filter. If the target lens is different, still use this one for adjustment then replace. Wrap the thread of the lens with the teflon tape for better thread fitting - 2 layers if enough. When screwing in make sure the tape does not get in the optical path.
- Focus adjustment screws - do not overtighten initially. Later, right before starting the procedure when the camera is against the pattern - turn it on, while in jpeg open the control interface and adjust the screws for the best manual focus (do not apply too much force).
Assembled setup
- Take a longer cable - at least 100mm
- Connect to port 0
- Set the camera address to 192.168.0.38
- Make sure the power supply provides the right voltage - 12V or 48V. If possible install PoE compatible power board - 10386.
Pattern
- Use the wallpaper pattern
- Make sure all 4 lasers are pointing in the right spots - "manual laser pointers" yellow button in the imagej plugin