Description

Logs external sensors data into a binary file marking it with local timestamps (micro-second resolution). It supports up to 4 sensor channels at the same time, e.g.: 1. IMU (Inertial Measurement Unit) - orientation in space 2. GPS - geographical location 3. External trigger signals from another Elphel camera. 4. Other sensor (e.g., odometer - 3..5V pulses).

A typical log record has the following format:

[LocalTimeStamp] [SensorData]
Examples or parsed records:
[LocalTimeStamp]: IMU: [wX] [wY] [wZ]  [dAngleX] [dAngleY] [dAngleZ] [accelX] [accelY] [accelZ] [veloX] [veloY] [veloZ] [temperature]
[LocalTimeStamp]: GPS: [NMEA sentence]
[LocalTimeStamp]: SRC: [MasterTimeStamp]