10359 fix

From ElphelWiki
Revision as of 18:17, 3 August 2010 by Andrey.filippov (talk | contribs) (Description)
Jump to: navigation, search

Description

There was a design error discovered in the 10359 & 10359A boards - due to a wrong source the sensors connected to J2, J3, J4 were powered from the 10359's 2.5V instead of the correct 3.3V coming from 10353. Because of that the linear regulators on the sensor board could not maintain nominal output voltage (2.5V, 2.8V) and isolate the analog from the digital supplies. Sensor did great job operating in such conditions in such a way that image deterioration was almost not noticeable - very faint vertical stripes with a 4-pixel period on a 10338D board. Older 10338A used different linear regulators and output voltage was slightly higher, so no vertical stripes were visible (but we would still recommend to replace (or fix 10359 boards as the noise level can be reduced when applying correct power).


The fix should be applied to all 10359 & 10359A boards.

ToFix

Fig.1 Modified Board

1

  • Connect the hole to the trace on the image.

2

  • With a 1mm drill isolate the top layer trace from the other layers. The top layer trace should not be cut.