Difference between revisions of "10393 power"
From ElphelWiki
(→12V) |
|||
Line 1: | Line 1: | ||
− | ==48V== | + | ==18-75V (48V)== |
+ | * DC-DC converter: TRACO POWER THD 12-4810WI, IN 18-75V, OUT 3.3V/3500mA | ||
+ | ===Notes=== | ||
+ | * Recommended connector for power: '''J3''' | ||
+ | ==9-36V (12V)== | ||
+ | * DC-DC converter: TRACO POWER THD 12-2410WI, IN 9-36V, OUT 3.3V/3500mA | ||
− | + | ===Notes=== | |
− | == | + | * Recommended connector for power: '''J4''' = bypass diodes to reduce voltage drop |
− | * | + | * '''J3''' is can be used only at 12+ V |
Revision as of 15:10, 8 June 2016
Contents
18-75V (48V)
- DC-DC converter: TRACO POWER THD 12-4810WI, IN 18-75V, OUT 3.3V/3500mA
Notes
- Recommended connector for power: J3
9-36V (12V)
- DC-DC converter: TRACO POWER THD 12-2410WI, IN 9-36V, OUT 3.3V/3500mA
Notes
- Recommended connector for power: J4 = bypass diodes to reduce voltage drop
- J3 is can be used only at 12+ V