Eyesis4Pi Calibration

From ElphelWiki
Jump to navigation Jump to search

Goniometer and IMU

Fig.1 Positive rotation angles in the calibration machine
Fig.2 Goniometer
Fig.3 IMU in Eyesis4π

IMU is ADIS 16375 - 2400 samples per second

During the calibration process the goniometer rotates the camera about 2 axes (y & z on Fig.1) by precisely known angles. To calibrate IMU one needs to match the goniometer angles with the IMU data. Notes:

  • The images are taken in the middle of the rest state of the goniometer.
  • IMU log contains 3 types of events: IMU data packet, GPS data packet, Image captured.
  • Images timestamps are recorded in the IMU log.

Calibration process output examples:

Camera 00:0E:64:08:1B:89 IMU calibration data:

Axial - angle about the z-axis in degrees (positive rotation is shown on Fig.1)
Tilt - angle about the y-axis in degrees (positive rotation is shown on Fig.1)

Links