Difference between revisions of "Eyesis4pi Post-Processing"
From ElphelWiki
(→Links) |
(→Instructions) |
||
Line 30: | Line 30: | ||
{| | {| | ||
|- valign="top" | |- valign="top" | ||
− | |[[File: | + | |[[File:Eyesis correction.png|thumb|800px|Eyesis corrections plugin interface]] |
|} | |} | ||
* '''Restore''' button -> browse for ''default_config.corr-xml'' (restores parameters for '''Configure correction''') | * '''Restore''' button -> browse for ''default_config.corr-xml'' (restores parameters for '''Configure correction''') |
Revision as of 16:26, 24 April 2017
Contents
Procedures
- Applying pixel mapping information
- Aberration correction
- Distortion correction
- Vignetting correction
- Color correction
- Denoising
- Sharpening
Requirements
- Linux OS (Kubuntu preferably).
- ImageJ and Elphel plugins.
- Hugin tools - enblend.
- ImageMagick - convert.
- PHP
- Get calibration kernels for the current Eyesis4Pi (come on a HDD with a camera).
- Get default-config.corr-xml (come on a HDD with a camera).
- Download footage from the camera.
Instructions
- Launch ImageJ from Eclipse
- Go to Plugins -> ImageJ-Elphel -> Eyesis Correction
Note: if plugin needs to be recompiled - Plugins -> Compile & Run. Find and select Eyesis_Correction.java.
- Restore button -> browse for default_config.corr-xml (restores parameters for Configure correction)
- Configure correction button - make sure that the following paths are set correctly (if not - mark the checkboxes - a dialog for each path will pop up):
Source files directory - directory with the footage images Sensor calibration directory - [YOUR-PATH]/calibration/sensors Aberration kernels (sharp) directory - [YOUR-PATH]/calibration/aberration_kernels/sharp Aberration kernels (smooth) directory - [YOUR-PATH]/calibration/aberration_kernels/smooth Equirectangular maps directory(may be empty) - [YOUR-PATH]/calibration/equirectangular_maps (it should be created automatically if the w/r rights of [YOUR-PATH]/calibration allow) Source file suffix - .jp4 if jp4 files are processed Sensor files prefix - the format is <prefix>NN.calib-tiff - <prefix> is blank if the files are just NN.calib-tiff. For XXX-NN.calib-tiff the prefix would be XXX- Sensor files suffix - default is .calib-tiff Kernel files (sharp)/(smooth) prefix - same rule as for the sensor files Kernel files (sharp)/(smooth) suffix - default is .kernel-tiff Equirectangular maps prefix - same rule as for the sensor files Equirectangular maps suffix - default is .eqr-tiff
- Configure warping (Skip if the files already exist) -> rebuild map files - this will create maps in [YOUR-PATH]/calibration/equirectangular_maps. Will take ~5-10 minutes.
- Select source files -> select all the footage files to be processed.
- Process files to start the processing. Depending on the PC power can take ~40 minutes for a panorama of (24+2) images.
- After processing is done there is only the blending step. It can be launched manually or from the WebGUI:
- WebGUI
- Manual blending: the following script scans directory for *.tiffs from ImageJ and uses enblend(to stitch into 16-bit tiffs) and converts them into jpegs, in terminal:
php stitch.php [source_directory] [destination_directory] - no slashes in the end of the paths
Links
- Eyesis4Pi 393 Main Article
- Workflow
- User Guide: Recording
- User Guide: Downloading footage
- User Guide: Post-Processing selected few panoramas
- User Guide - Post-processing: ImageJ